Why cooling the tank works

Your recovery machine pumps against tank pressure, and tank pressure is set by tank temperature. Ice a 100 °F tank down and the pressure falls with it: at 50 °F along the way, R-410A has already dropped from 319 to 143 psig. Incoming hot refrigerant warms the tank during recovery, and the freezer blocks keep absorbing that heat as it comes in — the tank starts colder, stays colder longer, and your head pressure stays down. Through extensive laboratory and field testing, our tank cooler has been able to save 25 – 50% of the time required to recover on both hot and moderate days.

Recovery tank saturation pressure at 100 and 50 degrees Fahrenheit by refrigerant
Refrigerant Tank at 100 °F Tank at 50 °F Pressure reduction
R-410A319 psig143 psig−55%
R-32326 psig146 psig−55%
R-454B301 psig135 psig−55%
R-134a124 psig45 psig−63%
R-22196 psig84 psig−57%